Skip to product information
1 of 2

OXEN HASH

Immersion Cooling Kit C2 12kW For Asic Miners Home Office Mining

Immersion Cooling Kit C2 12kW For Asic Miners Home Office Mining

Regular price R 50,000.00 ZAR
Regular price Sale price R 50,000.00 ZAR
Sale Sold out
Shipping calculated at checkout.
  • Utilize Flat Rate Shipping
  • Minimize Shipping Cost
  • Low-Cost Return 

SKU:

OXEN HASH Immersion Cooling for Crypto Mining

——Provide from Home Mining to Large-scale Mining Solutions

  • IMMERSION MINING KIT C2——Designed for Home Mining

Leakage Protection | Universal Wheels | Thermal Flow Optimization | Fluids Unloading Bolt | Higher Load

Compared to  C1

Completely redesigned, more than 30 details re-engineered, user experience improved.

Support for Various Models of Miners

Following rigorous testing, Immersion cooling kit now supports miners from Bitmain Antminer, Whatsminer and IceRiver KAS miners.

C2 12kW cooling capacity + Adaptive adjustment

Energy-saving solutions for most usage environments

  • At 35 °C, C2 can provide full 12kW cooling capacity. Each miner has a cooling margin of 2kW to support sufficient overclocking. 

  • The C2 dry cooler supports automatic frequency adjustment according to the temperature change of the coolant. It can respond to changes in ambient temperature in real-time, ensuring operation with the lowest power consumption.

Product Details

Front View

Top View

Back View

Specifications

1. C2 Tank

Outer Size 455(L)*508(W)*536(H)mm
17.91(L)*20(W)*21.1(H)in
Inner Size 398(L)*298(W)*392(H)mm
15.67(L)*11.73(W)*15.43(H)in
Net Weight 40.6kg/89.5Ib
Coolant Volume 80L
Input Voltage Single-phase 200-240V
50/60Hz
Power 180W(220V 50Hz)
Display 1.32”OLED Screen
Inlet/Outlet Temp 45/60℃

2. C2 Dry Cooler

Size 1076(L)*285(W)*531(H)mm
42.36(L)*111.22(W)*20.9(H)in
Power 5-400W(220V 50Hz)
Input Voltage Single-phase 200-240V 50/60Hz
Net Weight 43.3kg/95.5Ib
Intelligent Speed Tuning Automatically adjust the speedaccording to the temperature
Cooling Capacity 12kW@35℃12kW@95℉
Noise 68dB(A) 10m
EC Fan 2 pcs

Immersion Cooling Kit C2 Display

Application——Waste heat recovery scheme

C2 can meet your needs whether it is radiatorfloor heatingdomestic waterswimming pool. Heating while EARNING! This is a reference schematic and the actual situation should be considered when implementing it.

Immersion Cooling Kit C2 FAQ

Electrical questions

What is the connection method of the C2 power supply?

The mining rigs in C2 is directly connected to the power supply or PDU at home, and the tank and dry cooler are connected through standard C13 connectors.

What is the operating logic of the C2 fan? Can it be adjusted automatically?

Our C2 uses an EC fan to adjust the speed according to the temperature of the oil entering the tank (dry cooler oil temperature).There are 2 modes to choose (the mode is changed by a button inside the waterproof junction box outside the dry cooler).Press the button down is HEATING mode (waste heat utilization mode) 41.3℃ to start the dry cooler, 49.7℃ to maximize the dry cooler speed. Press the button up is NORMAL mode (normal operation mode), 20.5℃ to start the dry cooler, 28.9℃ to maximize the dry cooler speed.

How long is the pipeline for the C2 tank?

We provide two 5m pipeline as standard, and we also support customizing other lengths for a fee.

Will the tank automatically power on after a power outage?

Following a power outage, the tank is unable to initiate an automatic startup and necessitates manual activation by clicking on the screen.

View full details